An EEG report that says “epileptiform discharges” carries weight: it can turn a faint or an unexplained spell into a diagnosis of epilepsy. Yet a sharp-looking wave is not always a spike. Normal background rhythms and benign variants can look sharp, and even experts do not always agree on what they see. This article looks at the research on which EEG patterns are overread, how often experts agree on interictal epileptiform discharges (spikes and sharp waves between seizures), whether written criteria help, how reliably intensive care EEG patterns are classified, and what is known about learning to read EEG. Numbers in brackets refer to the references at the end.

A clinician in a face mask and gloves holds up a sheet of brain MRI scans to review them

Photo: Anna Shvets, via Pexels.

Which EEG patterns get overread as epileptiform?

Benbadis and Tatum reviewed EEGs of patients who were eventually diagnosed with psychogenic nonepileptic seizures but had earlier had an EEG read as epileptiform. 15 of the actual recordings were available for review [1].

  • The overread patterns were wicket spikes (1 record), hypnagogic hypersynchrony (1) and hyperventilation-induced slowing (1) [1].
  • In the other 12 records, the overread patterns were simple fluctuations of sharply contoured background rhythms or fragmented alpha activity [1].

A later series from the same epilepsy clinic included 37 patients who were ultimately diagnosed with conditions other than epilepsy, had previously had an EEG read as showing epileptiform discharges, and whose EEG could be re-reviewed [2].

  • Eventual diagnoses were psychogenic nonepileptic seizures (10), syncope (7), other miscellaneous diagnoses (5) and unexplained nonspecific symptoms (15) [2].
  • None of the EEGs had epileptiform discharges [2].
  • The original reports described “temporal sharp waves” in 30, “frontal sharp waves” in 2 and “generalized spike-wave complexes” in 2; three had no report available [2].
  • The patterns mistaken for temporal and frontal sharp waves were simple fluctuations of background activity with temporal phase reversals [2].

The authors concluded that, rather than well-described normal variants, the overinterpreted patterns tend to be normal fluctuations of the background [1], and that by far the most common pattern overread as epileptiform is nonspecific fluctuation of the background in the temporal regions, misread as temporal sharp waves [2]. A review by Kang and Krauss adds that benign variants such as wicket spikes, small sharp spikes and rhythmic mid-temporal theta of drowsiness are also misclassified as epileptiform discharges, which can delay the diagnosis of conditions such as psychogenic nonepileptic seizures, anxiety or panic disorders and near syncope [3].

What this means: the commonest trap was not an exotic variant but ordinary background activity that happens to look sharp, especially over the temporal lobes. A phase reversal alone does not make a wave epileptiform.

How often do experts agree on spikes?

In a study of routine EEGs from the Massachusetts General Hospital, 9 experts first marked candidate discharges in 991 EEGs reported to contain at least one interictal epileptiform discharge. The candidates were grouped by shape, and 13 262 representative waveforms (including 660 from EEGs reported as free of discharges) were then scored as epileptiform or not by 8 experts independently [4].

  • For individual candidate discharges, agreement was fair: mean percentage of agreement 72.4% (95% CI 67.0%–77.8%) and mean Gwet κ 48.7% (95% CI 37.3%–60.1%) [4].
  • For whether an EEG contained any discharges at all, agreement was substantial: mean percentage of agreement 80.9% (95% CI 76.2%–85.7%) and mean κ 69.4% (95% CI 60.3%–78.5%) [4].
  • A statistical model based on waveform shape, with an individual threshold for each expert, explained the experts’ scores with an accuracy of 80% (range 73%–88%) [4].

The authors suggested that experts can identify whether an EEG contains discharges with substantial reliability, and that the lower agreement on individual discharges may be largely explained by experts applying different thresholds to a common underlying model [4].

What this means: experts largely see the same features but differ in how sharp or how distinct a wave must be before they call it a spike. Borderline waves are where readers disagree most, and where a cautious threshold matters.

Do written criteria for spikes help?

The International Federation of Clinical Neurophysiology (IFCN) lists six features of an interictal epileptiform discharge: (1) a di- or tri-phasic wave with a sharp or spiky (pointed) peak; (2) a different wave duration from the ongoing background; (3) an asymmetric waveform; (4) a following slow after-wave; (5) disruption of the surrounding background; and (6) a distribution of negative and positive potentials on the scalp that suggests a source in the brain [5].

Kural and colleagues tested these criteria, noting that criteria with high specificity are needed because EEG over-reading is a common cause of epilepsy misdiagnosis. Seven raters reviewed sharp transients from 100 patients with and without epilepsy, whose diagnosis was established by video-EEG recording of their habitual events [5].

  • Using 4 or 5 criteria as a cutoff gave an accuracy of 91% and 88%, similar to unrestricted expert scoring (92%) [5].
  • Requiring 5 criteria gave a specificity of 95.65% with a sensitivity of 81.48% [5].

The authors concluded that the presence of 5 IFCN criteria is optimal for clinical use [5].

A later study asked whether the criteria make experts agree more. Nine EEG experts rated the same 200 candidate discharges twice, at least 30 days apart, selecting the applicable IFCN criteria in the second round [6].

  • There were no major differences in performance (area under the curve 0.90 vs 0.91) or in inter-rater reliability (AC1 0.48 vs 0.47) between the two rounds [6].
  • Agreement was only fair for criteria 2, 3, 5 and 6, and moderate for criteria 1 and 4 [6].

The authors concluded that the IFCN criteria may not significantly improve agreement, performance or calibration among experts [6].

What this means: the criteria are a useful checklist for asking “is this really a spike?”, and a strict cutoff favors specificity. But simply adding the checklist did not make experts agree more, because judging each feature is itself subjective.

Patterns in the intensive care unit

Critical care EEGs contain many periodic and rhythmic patterns of uncertain significance. To test the American Clinical Neurophysiology Society (ACNS) critical care EEG terminology (2012 version), 49 readers with a broad range of EEG experience reviewed a set of training slides and then answered 11 identical questions for each of 37 EEG samples [7].

  • Agreement (κ) was almost perfect (90%–100%) for whether a pattern was an electrographic seizure, for the pattern’s location and type, and for sharpness, absolute amplitude, frequency and number of phases, among other terms [7].
  • Agreement was substantial for the +F and +R modifiers (66% and 67%) and moderate for triphasic morphology (58%) [7].
  • Agreement was only fair for evolution (21%) [7].

The authors concluded that agreement for most terms in the terminology is high [7].

What this means: with shared definitions and a set of training slides, readers agreed well on naming most periodic and rhythmic patterns. Deciding whether a pattern evolves was far less reliable, so it deserves particular care.

Can practice with feedback improve spike recognition?

Barfuss and colleagues created a public EEG test within the iOS app DiagnosUs, using a pool of 13 262 candidate discharges. Users rated each candidate as epileptiform or not and received immediate feedback based on a gold standard [8].

  • The analysis included 901 participants [8].
  • Users achieved a mean improvement of 13% over 1,000 questions, with an ending accuracy of 81% [8].
  • Some types of candidate waveforms remained challenging for most users even after substantial practice [8].

The authors concluded that users improved through repeated exposure and immediate feedback, and that this kind of app-based activity has potential as a supplemental tool for teaching neurology trainees [8].

Formal training is uneven. In a survey of US adult neurology residency program directors (47 of 161, 29%, responded), the mean number of 1-month EEG rotations required to graduate was 1.7 (range 0–4). The number of EEGs read during a typical rotation varied from more than 40 in about one-third of programs to 0–10 in about 14%, and 64% of program directors reported not using objective measures to assess EEG milestones. The most commonly reported barrier was insufficient EEG exposure (32%) [9].

Objective measurement is possible. In a 2026 feasibility study that modeled spike-detection skill from thousands of rated EEG segments, a pass threshold set in one half of the data was applied to the other half: 100% of experts (14/14) passed, compared with 14% of novices (1/7) and 0% of residents (0/11) [10].

What this means: recognition of epileptiform discharges improved with many examples and immediate feedback, but that study measured progress on the app’s own questions, not on clinical EEG reading. Many trainees read relatively few EEGs and are rarely tested objectively, which leaves room for structured practice alongside supervised reading.

Lessons for learning EEG

  1. Know the normal background well. Most overread “sharp waves” were ordinary fluctuations of background activity or fragmented alpha, especially over the temporal regions [1][2].
  2. Learn the benign variants next to the patterns they mimic. Wicket spikes, small sharp spikes and rhythmic mid-temporal theta of drowsiness are among the patterns misclassified as epileptiform [3].
  3. Do not let a phase reversal decide for you. The benign patterns overread as temporal sharp waves had temporal phase reversals too [2].
  4. Check a candidate spike against the IFCN features, and set a high bar. A strict cutoff of 5 criteria gave a specificity of 95.65% [5], although the checklist alone did not make experts agree more [6].
  5. Read the EEG in the light of the clinical story. Viewing the EEG as confirmatory of a clear clinical diagnosis helps avoid misdiagnosing epilepsy [3].
  6. In the intensive care unit, use the standard terminology and take extra care with evolution. It was the feature readers agreed on least [7].
  7. Practice with many examples and immediate feedback. Learners improved over 1,000 questions with feedback after each answer [8], and insufficient exposure is the main barrier reported in residency training [9].

Practice with EEG Bootcamp

EEG Bootcamp teaches you to recognize EEG patterns step by step, with short lessons, practice rounds and a pattern library, and feedback after every answer. It is designed for medical students, neurology and intensive care trainees, EEG technologists and other learners.

EEG Bootcamp quiz screen: an N2 sleep page with vertex sharp transients, with the answer chosen from sleep spindles, K-complexes and vertex sharp transients, followed by an explanation of the correct answer EEG Bootcamp page showing centrotemporal spikes, with a menu to switch between longitudinal bipolar, transverse bipolar and average reference montages

  • A few patterns at a time: 17 short lessons in 8 stages, from the awake EEG, sleep and artifacts, to benign variants and epileptiform discharges, to slowing, seizures and periodic and coma patterns. Each lesson introduces a few patterns on teaching cards, then asks you to tell them apart from their look-alikes.
  • Feedback after each answer: you see what the page showed and how to recognize it. Pass a lesson to open the next one, and keep a daily streak going.
  • Practice rounds: ten pages in random order; choose normal pages (rhythms, sleep, benign variants and artifacts), abnormal pages or a mix of everything.
  • Read the page as you would at work: 19 electrodes of the 10-20 system, with longitudinal bipolar (double banana), transverse bipolar and average reference montages from the same recording, so fields and phase reversals stay consistent. Adjust the sensitivity and page length, play or pause, ask for a new example, and use hints that mark where to look.
  • Pattern library: 37 entries, each with an example page, a head map of where it shows, how to recognize it, what it means and what it can be confused with. Search it and bookmark what you want to review.
  • Synthesized and real EEG: lessons, practice and the library use EEG pages synthesized on your device. A Real recordings practice round (Pro) shows short excerpts of real, de-identified EEG from openly licensed research datasets. Real EEGs are more varied and less tidy, so use the app alongside supervised training and textbooks.
  • Free and Pro: free with the first three stages, the whole pattern library and two practice rounds a day; Pro is an optional one-time purchase that opens every lesson, unlimited practice and the Real recordings round. Works offline, with no account and no ads, in English and Vietnamese.

Download on Android: EEG Bootcamp on Google Play
The iPhone version is in App Store review.

Read more: Why Auscultation Is Hard, and What Research Says About Getting Better

Disclaimer: this article is for educational purposes only and is not a substitute for formal clinical training or professional medical advice. The studies cited did not evaluate EEG Bootcamp. EEG Bootcamp is not a medical device and must not be used for clinical decisions.

References

  1. Benbadis SR, Tatum WO. Overintepretation of EEGs and misdiagnosis of epilepsy. J Clin Neurophysiol. 2003;20(1):42–44. doi:10.1097/00004691-200302000-00005. PMID 12684557
  2. Benbadis SR, Lin K. Errors in EEG interpretation and misdiagnosis of epilepsy. Which EEG patterns are overread? Eur Neurol. 2008;59(5):267–271. doi:10.1159/000115641. PMID 18264016
  3. Kang JY, Krauss GL. Normal variants are commonly overread as interictal epileptiform abnormalities. J Clin Neurophysiol. 2019;36(4):257–263. doi:10.1097/WNP.0000000000000613. PMID 31274688
  4. Jing J, Herlopian A, Karakis I, Ng M, Halford JJ, Lam A, et al. Interrater reliability of experts in identifying interictal epileptiform discharges in electroencephalograms. JAMA Neurol. 2020;77(1):49–57. doi:10.1001/jamaneurol.2019.3531. https://pmc.ncbi.nlm.nih.gov/articles/PMC6806666/
  5. Kural MA, Duez L, Sejer Hansen V, Larsson PG, Rampp S, Schulz R, et al. Criteria for defining interictal epileptiform discharges in EEG: a clinical validation study. Neurology. 2020;94(20):e2139–e2147. doi:10.1212/WNL.0000000000009439. https://pmc.ncbi.nlm.nih.gov/articles/PMC7526669/
  6. Yuan D, Katyal R, Sheikh I, Karakis I, Benbadis S, Amin U, et al. Utility of the IFCN criteria for identifying interictal epileptiform discharges by experts: a decision hygiene approach to improve inter-rater reliability. Clin Neurophysiol. 2025;173:138–146. doi:10.1016/j.clinph.2025.02.275. https://pmc.ncbi.nlm.nih.gov/articles/PMC12335889/
  7. Gaspard N, Hirsch LJ, LaRoche SM, Hahn CD, Westover MB; Critical Care EEG Monitoring Research Consortium. Interrater agreement for Critical Care EEG Terminology. Epilepsia. 2014;55(9):1366–1373. doi:10.1111/epi.12653. https://pmc.ncbi.nlm.nih.gov/articles/PMC4879939/
  8. Barfuss JD, Nascimento FA, Duhaime E, Kapur S, Karakis I, Ng M, et al. On-demand EEG education through competition – a novel, app-based approach to learning to identify interictal epileptiform discharges. Clin Neurophysiol Pract. 2023;8:177–186. doi:10.1016/j.cnp.2023.08.003. https://pmc.ncbi.nlm.nih.gov/articles/PMC10480673/
  9. Nascimento FA, Gavvala JR. Education research: neurology resident EEG education: a survey of US neurology residency program directors. Neurology. 2021;96(17):821–824. doi:10.1212/WNL.0000000000011354. PMID 33310878
  10. Zhang T, Nascimento FA, Karakis I, Keldsen EW, Sun C, Jing J, et al. An adaptive, variable-length test for certifying electroencephalographic spike-detection skill: a retrospective feasibility study. Epilepsia. 2026. doi:10.1002/epi.70519. PMID 42858246