Atrial fibrillation is the classic “irregularly irregular” rhythm, and the first clue often comes from a fingertip on the wrist or a stethoscope on the chest. But how reliable are these bedside checks? This article looks at the research on pulse palpation for atrial fibrillation, what happens when an irregular pulse is checked with an ECG, how accurately we count the heart rate in atrial fibrillation, and whether a stethoscope with artificial intelligence can recognize the rhythm. Numbers in brackets refer to the references at the end.

A gloved healthcare professional feels the radial pulse at a patient’s wrist

Photo: Mikhail Nilov, via Pexels.

How good is the pulse at picking up atrial fibrillation?

A systematic review searched for studies that compared pulse palpation with an ECG diagnosis of atrial fibrillation. It found 3 studies with 2385 patients [1].

  • Sensitivity of pulse palpation ranged from 91% to 100%, and specificity from 70% to 77% [1].
  • Pooled sensitivity was 94% (95% CI 84%–97%) and pooled specificity 72% (95% CI 69%–75%) [1].
  • The pooled positive likelihood ratio was 3.39 and the pooled negative likelihood ratio 0.10 [1].
  • Assuming 3% of patients older than 65 have undetected atrial fibrillation, the authors estimated that opportunistic pulse palpation would find an irregular pulse in 30% of those screened, all needing an ECG, and that 0.2% of those screened would have atrial fibrillation missed by the pulse check [1].

The authors concluded that pulse palpation has a high sensitivity but relatively low specificity, so it is useful for ruling out atrial fibrillation and may be a useful opportunistic screen [1].

What this means: a regular pulse makes atrial fibrillation much less likely at the moment you check. An irregular pulse is a reason to get an ECG, not a diagnosis.

Pulse versus a 30-second ECG in a screening study

In the Swedish STROKESTOP II screening study, 6159 people aged 75/76 years had their radial pulse palpated for 30 seconds by healthcare professionals, recorded as regular or irregular, followed by a 30-second single-lead ECG [2].

  • 461 participants (7.5%) had an irregular pulse; 22 of them (4.8%) were diagnosed with atrial fibrillation on the single-lead ECG [2].
  • Among those with a regular pulse, 6 (0.1%) new cases of atrial fibrillation were found [2].
  • Sensitivity of pulse palpation was 78.6% and its positive predictive value 4.8% [2].
  • A history of palpitations did not predict atrial fibrillation [2].

The authors concluded that pulse palpation was inferior to the single-lead ECG for screening and advocated the ECG rhythm strip instead [2].

What this means: in a screening setting with few new cases, most irregular pulses were not atrial fibrillation, and some cases were missed. The sensitivity here was lower than in the earlier review, so a pulse check alone is not enough when the goal is to find new atrial fibrillation.

The ECG has to be read well, too

As part of the SAFE trial, ECGs from 2595 patients aged 65 or over were assessed by 49 general practitioners, 49 practice nurses and interpretative software, against two independent specialists as the reference [3].

  • General practitioners detected 79 of 99 cases of atrial fibrillation on a 12-lead ECG (sensitivity 80%, 95% CI 71% to 87%) and misread 114 of 1355 sinus rhythm ECGs as atrial fibrillation (specificity 92%) [3].
  • Practice nurses had a similar sensitivity (77%) but a lower specificity (85%) [3].
  • The software had a specificity of 99% but missed 36 of 215 cases (sensitivity 83%); combining it with the general practitioner’s reading gave a sensitivity of 92% and a specificity of 91% [3].

The authors concluded that many primary care professionals cannot accurately detect atrial fibrillation on an ECG, and that the ECG should be read by appropriately trained people [3].

What this means: the bedside check and the ECG are two steps, and both can go wrong. When an irregular pulse leads to an ECG, the reading matters as much as the recording.

Counting the heart rate in atrial fibrillation: apical or radial?

In a study of 94 nurses (registered nurses, licensed practical nurses, nursing students and clinical specialists or faculty), each nurse took six pulse measurements of one man in chronic atrial fibrillation: apical and radial, each counted over 15, 30 and 60 seconds. The results were compared with simultaneous ECG and plethysmographic recordings [4].

  • The man’s heart rate varied from 57 to 111 beats/min (mean 81 beats/min) [4].
  • The mean absolute error of the six measurements ranged from 8 to 20 beats/min, all considered clinically important when a 10% error was used as the criterion [4].
  • The apical method was significantly more accurate than the radial method, against both standards [4].
  • The 60-second count was significantly more accurate, although the differences between counting intervals were not considered clinically significant [4].

The authors described atrial fibrillation as one of the most difficult rhythms to count and found heart rate measurement in the study quite inaccurate [4].

What this means: in atrial fibrillation, the radial pulse was the less accurate way to count. Counting at the apex for a full minute was the most accurate method in this study, but every method in it missed the true rate by a clinically important margin.

Can a stethoscope with artificial intelligence recognize atrial fibrillation?

A retrospective study used 496 heart sound recordings from patients with and without atrial fibrillation to develop and test an AI model for an electronic stethoscope [5].

  • In the validation dataset, sensitivity was 0.94 (95% CI 0.88–0.98), specificity 0.91 (95% CI 0.83–0.96) and the area under the ROC curve 0.93 (95% CI 0.88–0.97) [5].
  • When heart sounds were recorded twice, on non-consecutive days, in 74 people, the model’s judgments agreed with a Cohen’s kappa of 0.74 [5].

The authors concluded that the AI-based electronic stethoscope shows promise for atrial fibrillation screening [5].

What this means: in this dataset, software recognized atrial fibrillation from heart sound recordings. This was a single retrospective study of recordings, so it shows potential, not proven performance in everyday screening. For AI-enabled stethoscopes and murmurs, see our article on heart murmurs and gallops.

Lessons for checking the heart rhythm at the bedside

  1. Use a regular pulse to rule out, not an irregular pulse to rule in. Pulse palpation is sensitive but not specific for atrial fibrillation [1].
  2. Confirm an irregular pulse with an ECG. In screening, fewer than 1 in 20 people with an irregular pulse had atrial fibrillation, and a 30-second single-lead ECG performed better than the pulse [2].
  3. Make sure the ECG is read by someone trained to read it. General practitioners and nurses both missed cases and over-called atrial fibrillation [3].
  4. In atrial fibrillation, count the apical rate for a full minute. The apical method was more accurate than the radial pulse, and the 60-second count was the most accurate [4].
  5. Treat AI stethoscopes as promising but early. Good results on recorded sounds still need confirmation in prospective studies [5].

Practice with Lung Heart Sounds

Lung Heart Sounds is an auscultation trainer with 31 heart sounds and 16 lung sounds, including a group of heart rhythms, for medical, nursing and paramedic students, residents and anyone who wants a sharper ear with the stethoscope.

Lung Heart Sounds quiz screen: listen to a recording, then choose between atrial fibrillation, mitral valve prolapse, late systolic murmur and pericardial knock Lung Heart Sounds spectrogram view of mitral regurgitation with S1 and S2 marked, the auscultation site on a chest diagram and 0.5× speed

  • Heart rhythms (Pro): atrial fibrillation, AV block (first degree, second degree and complete) and sinus tachycardia.
  • See what you hear: a live phonocardiogram with S1 and S2 marked, a spectrogram view (Pro) and half-speed (0.5×) playback (Pro).
  • Loop any sound: every sound loops, so you can listen as long as you need.
  • Quiz mode: 10 questions per round, listen to a sound and choose the right name from 4 options; 2 free rounds every day, unlimited with Pro.
  • Free and Pro: free to download with 32 heart and lung sounds; Pro is a one-time purchase, not a subscription. Works offline, with no account and no ads.

Download on iOS: Lung Heart Sounds on the App Store
Download on Android: Lung Heart Sounds on Google Play

Read more: Heart and Lung Auscultation: A Practical Guide for Students · Telling Heart Murmurs Apart · Why Auscultation Is Hard, and What Research Says About Getting Better

Disclaimer: this article is for educational purposes only and is not a substitute for formal clinical training or professional medical advice. The studies cited did not evaluate Lung Heart Sounds. Lung Heart Sounds is not a medical device and must not be used to diagnose or treat any condition.

References

  1. Cooke G, Doust J, Sanders S. Is pulse palpation helpful in detecting atrial fibrillation? A systematic review. J Fam Pract. 2006;55(2):130–134. PMID 16451780
  2. Gudmundsdottir KK, Fredriksson T, Svennberg E, Al-Khalili F, Friberg L, Häbel H, et al. Performance of pulse palpation compared to one-lead ECG in atrial fibrillation screening. Clin Cardiol. 2021;44(5):692–698. doi:10.1002/clc.23595. https://pmc.ncbi.nlm.nih.gov/articles/PMC8119837/
  3. Mant J, Fitzmaurice DA, Hobbs FD, Jowett S, Murray ET, Holder R, et al. Accuracy of diagnosing atrial fibrillation on electrocardiogram by primary care practitioners and interpretative diagnostic software: analysis of data from screening for atrial fibrillation in the elderly (SAFE) trial. BMJ. 2007;335(7616):380. doi:10.1136/bmj.39227.551713.ae. https://pmc.ncbi.nlm.nih.gov/articles/PMC1952490/
  4. Sneed NV, Hollerbach AD. Accuracy of heart rate assessment in atrial fibrillation. Heart Lung. 1992;21(5):427–433. PMID 1399661
  5. Guo Y, Lin H, Chen H, Wu X, Luo Y. Detection of atrial fibrillation via artificial intelligence-assisted auscultation. BMC Cardiovasc Disord. 2025;25(1):795. doi:10.1186/s12872-025-05236-z. https://pmc.ncbi.nlm.nih.gov/articles/PMC12595621/